Hp printers — install and use the hp smart app (windows 10)

Release Notes

End User License Agreements:HPE Software License Agreement v1Hewlett-Packard End User License Agreement

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Important:

HPE SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.  HPE Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HPE SSA, with the appropriate firmware.

HPE SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices.  Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Notes:

For support for HPE SSA or Smart Array controllers, please visit .

Users will automatically be logged out after a predetermined period of inactivity when using HPE SSA and will have to re-login.

On the Web-based Management Device Homepage, under «options», «Anonymous Access» should be enabled when using HPE SSA.

When clicking on a controller that is currently being configured in a different HPE SSA session, a message will appear which allows you to override the other HPE SSA session or cancel. If you choose to override the other HPE SSA session, any unsaved changes in the other session will be discarded.

To uninstall HPE SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.

To run HPE SSA in local application mode on Windows, Internet Explorer must be the default browser.

The following are known issues:

Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with
this MD5 Checksum value:

405981b7e53faec5827d45ce4c022eab 580134-024.iso

Installation:

To make a physical CD from an ISO image file, download the zip file to a temporary directory and extract the ISO image to that directory.In order to create a CD from this ISO image, you must use a software utility capable of writing an ISO file to a recordable media such as CD-R.

Note: Simply copying the ISO file to a CD-R will NOT result in a usable CD. HP recommends you run MD5 Checksum on the Zip file and/or ISO image prior to burning the CD. HP also recommends that you turn the verify feature «ON».

Description

The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HPE SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HPE Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HPE SSA, with the appropriate firmware.

HPE SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Important

HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.  HP Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HP SSA, with the appropriate firmware.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices.  Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Установка программного обеспечения для устройства,подключенн.

Установка программного обеспечения для устройства,подключенного к сети

Выполните приведенные ниже пункты, если устройство уже подключено к сетевомукомпьютеру (т.е. устройству уже присвоен IP-адрес) и необходимо установить драйверпринтера на другой компьютер.

Откройте встроенный Web-сервер HP в компьютере. См.

Щелкните на вкладку HP Smart Install.

Нажмите кнопку Загрузка.

Для завершения установки устройства выполните инструкции на экране.

Создание однорангового (компьютер-компьютер) беспроводногоподключения

Данное устройство может подключаться к компьютеру при помощи однорангового (компьютер-компьютер) беспроводного соединения.

Включите устройство и восстановите настройки сетевого подключения.

Распечатайте страницу конфигурации (см.

разделе «Информация о сети» найдите сетевое имя (SSID).

Обновите список доступных беспроводных сетей на компьютере, щелкните на сетевоеимя устройства (SSID) и подключитесь к нему.

Через несколько минут распечатайте страницу конфигурации и найдите на ней IP-адресустройства.

Откройте web-браузер и введите IP-адрес устройства в адресную строку. Нажмитеклавишу

, чтобы открыть встроенный Web-сервер HP.

Щелкните на вкладку HP Smart Install, а затем нажмите кнопку Загрузка для установкипрограммного обеспечения.

На расположенных ниже рисунках показано различие между соединением «компьютер-компьютер» и сетевым подключением через точку доступа (инфраструктура).

Сетевое подключение (только для беспроводных моделей)

Installation Instructions

Prerequisites:

This utility requires the following minimum firmware revisions:

  • Integrated Lights-Out 3 firmware v1.00 or later
  • Integrated Lights-Out 4 firmware v1.00 or later
  • Integrated Lights-Out 5 firmware v1.30 or later

The management interface driver must be installed on the server.

Microsoft .Net Framework 2.0 or later is required to launch HPONCFG GUI.

To ensure the integrity of your download, HPE recommends verifying your results with
the following SHA-256 Checksum values:

369046a31078030b12dc28c0bcbfa545a77b75004bc6bd8a7e7b9e7a858d331e cp037416.compsig
8e99879db8e01b09fcdeff085e05f4fcdf5c7a7901dd732a190f1a87702238e4 cp037416.exe

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Uninstall any older version of HPONCFG before installing this version of HPONCFG.

Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.

Click on the install button to install the utlility on the server. This does not require a reboot.

The utility will be installed in the program files under the directory HewlettPackardEnterprise\HPONCFG\

A shortcut for the graphical interface of the utility will be provided in «Start Menu > Programs > HPE System Tools > HP Lights-Out Online Configuration Utility».

Best practices for resolving utility issues

A clean and tidy computer is the key requirement for avoiding problems with utility. This means running a scan for malware, cleaning your hard drive using 1cleanmgr and 2sfc /scannow, 3uninstalling programs that you no longer need, checking for Autostart programs (using 4msconfig) and enabling Windows’ 5Automatic Update. Always remember to perform periodic backups, or at least to set restore points.

Should you experience an actual problem, try to recall the last thing you did, or the last thing you installed before the problem appeared for the first time. Use the 6resmon command to identify the processes that are causing your problem. Even for serious problems, rather than reinstalling Windows, you are better off repairing of your installation or, for Windows 8 and later versions, executing the 7DISM.exe /Online /Cleanup-image /Restorehealth command. This allows you to repair the operating system without losing data.

To help you analyze the utility.exe process on your computer, the following programs have proven to be helpful: ASecurity Task Manager displays all running Windows tasks, including embedded hidden processes, such as keyboard and browser monitoring or Autostart entries. A unique security risk rating indicates the likelihood of the process being potential spyware, malware or a Trojan. BMalwarebytes Anti-Malware detects and removes sleeping spyware, adware, Trojans, keyloggers, malware and trackers from your hard drive.

Translation

To help in USB Oblivion translation you’ll need to perform next steps:

  1. Download and install poEdit utility;
  2. Download USBOblivion.pot (translation template);
  3. Translate it by poEdit to your language;
  4. Save to file under name «USBOblivion32.exe.XX.po» or «USBOblivion64.exe.XX.po» near USBOblivion32.exe or USBOblivion64.exe correspondingly. Where «XX» is a 2- or 4-digit hexadecimal primary language identifier for example «09» — English, «19» — Russian, «07» — German, etc.
  5. Test it. Application loads translation according to the default Windows language. To select any other language you must specify a command-line option «-lang:XX» (without quotes) where XX is a hexadecimal language code.
  6. Send PO-file to me raspopov@cherubicsoft.com please.

Complete translations:

  • English (built-in)
  • Simplified Chinese

  • German

  • Italian

  • Polish

  • Russian

Incomplete translations:

  • Greek

  • French

  • Spanish

  • Korean

  • Dutch

  • Brazilian Portuguese

  • Swedish

  • Turkish

  • Czech

Translation for USB Oblivion provided by my «PO-Localization 1.0.0.4» library.

Enhancements

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Support for:
Smart Array P430
Smart Array P431
Smart Array P731m

Features supported with appropriate firmware versions and devices as base features (no longer requires SAAP license keys):

Drive Erase
Heal Array
HP SmartCache
HP SSD Smart Path
HP SmartSSD Wear Gauge
Online Expansions and Extensions of Arrays and Logical Drives
Moving and Deleting of Individual Logical Drives
 

  • Removes previous limitation of having to delete all logical drives in order until target was reached
  • Allows moving from one drive type to another…SATA to SAS, SAS to SATA

Advanced Capacity Expansions
Split Mirror Backup and Rollback
Online Mirror Splitting with Recombining in Offline Mode
Online RAID Migrations
Online Strip Size Migrations
Mismatched Drive Firmware Notifications

Supports following RAID levels as base features (no longer requires SAAP license keys):

  • RAID 0
  • RAID 1, RAID 1(ADM, Advanced Data Mirroring)
  • RAID 10, RAID 10(ADM, Advanced Data Mirroring)
  • RAID 5
  • RAID 50
  • RAID 6
  • RAID 60

Rapid Parity Initialization
Shrink Array, Move Array, and Replace Array
Spare Management

  • Dedicated (multiple arrays covered by one spare)
  • Auto-Replace Drive (spare becomes data replacement drive and covers RAID 0 when set in Predictive Spare Mode)

VOD Performance Optimization — Video on Demand

Description

The Offline HP Smart Storage Administrator (HP SSA) provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows.

This deliverable will allow users to boot into an environment from which they can choose various configuration utilities (HP SSA, HPSSACLI, and HPSSASCRIPTING) prior to the Host OS loading.

The HP Smart Storage Administrator (HP SSA) helps you configure, manage, diagnose, and monitor HP ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HP Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with
this MD5 Checksum value:

989609f1fc8b2bbc0c73b30299bac355 hpssaoffline-1.50-4.0-x86.zip

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Download the Offline HP Smart Storage Administrator zip file and then burn/write the ISO image to the desired media (CD/DVD/USB Key/SD card) using the HP USB Key Utility for Windows

Insert the media into the server and boot the server.  Verify that your system can boot from the desired media.

A menu with the three boot options (HP SSA, HPSSACLI, HPSSASCRIPTING) is shown. The user can manually select which utility to start; or if no selection is made, HP SSA is automatically started.

This image is a bootable environment that immediately starts HP SSA to allow configuration of storage.

This ISO image can also be mounted as a CD image through ILO2 or higher.  It is highly recommended that your server have the latest BIOS firmware and latest ILO2  or higher firmware installed.

This utility provides the following boot options:

   *   The web based HP Smart Storage Administrator (HP SSA)

   *   The command line HP Smart Storage Administrator (HPSSACLI)

   *   The Scripting HP Smart Storage Administrator (HPSSASCRIPTING)

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with
this SHA-256 Checksum value:

354b65016ceb9cb11a417c76aeba4079ac74f9a430588c0e9d7e633f4caa3a1f cp029559.exe

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:

If there is an older version of HPE SSA installed on the system, please uninstall it by going to «Control Panel -> Uninstall a program» and then uninstall «HP Smart Storage Administrator».

Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the «Install» button to proceed with the installation. The utility will automatically be installed.

Usage

USBOblivion.exe 

Parameters

  • -enable — Do real clean (simulation otherwise)
  • -auto — Automatic run
  • -nosave — Don’t save backup .reg-file
  • -save:filename — Save a registry backup to this file (default: save it to My Documents)
  • -log:filename — Save working log to this file
  • -lang:XX — Use language XX (hex-code)
  • -silent — Hidden mode (if possible)
  • -norestorepoint — Don’t create a System Restore Point
  • -norestart — Don’t restart Windows
  • -noexplorer — Don’t close Windows Explorer
  • -? — Show this help

Languages

  • -lang:04 — Simplified Chinese (by 天路)
  • -lang:07 — German (by Steven, Kristine Baumgart)
  • -lang:08 — Greek (by Geogeo)
  • -lang:09 — English (by Nikolay Raspopov)
  • -lang:0a — Spanish (by Boris Gilmar Terrazas Miranda, CesarRG)
  • -lang:0c — French (by Miel, Mathieu Bergounioux, Rico-sos)
  • -lang:10 — Italian (by Marcello Gianola)
  • -lang:12 — Korean (by 4Li)
  • -lang:13 — Dutch (by Jeroen Westera)
  • -lang:15 — Polish (by dmocha)
  • -lang:16 — Brazilian Portuguese (by Paulo Guzmán, Newton Apostolico)
  • -lang:19 — Russian (by Nikolay Raspopov)
  • -lang:1d — Swedish (by Ake Engelbrektson)
  • -lang:1f — Turkish (by Murat)
  • -lang:20 — Czech (by Jaaka)

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with
the following SHA-256 Checksum values:

1e67c8617074296aa3223aed4e37546ca71075e9e62fcf50f8d30f041381625c cp036448.exe
18a11b063844c50f95b967ffaa16446e60047de0333db27182a010391e617f5f cp036448.compsig

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:

If there is an older version of HPE SSA installed on the system, please uninstall it by going to «Control Panel -> Uninstall a program» and then uninstall «HP Smart Storage Administrator».

Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the «Install» button to proceed with the installation. The utility will automatically be installed.

Release Notes

End User License Agreements:Hewlett-Packard End User License Agreement

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

*** New ***

Starting with versions 8.75.12.0, an Offline version of ACU is available from www.hp.com that allows users to boot directly into the configuration and maintenance utilities prior to any Host OS loading or being installed.

This new deliverable of ACU is available for download through normal software methods (such as searching by Server model, OS, or device) or by searching for ‘HP ProLiant Offline Array Configuration Utility’

Notes:For support for ACU or Smart Array controllers, please visit Contact HP.

For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.

The legacy ACU (native win32 application) and ACU executables can not be run on the same server at the same time; however, configurations created with one utility should be compatible with those created by the other.

Users will automatically be logged out after a predetermined period of inactivity when using ACU and will have to re-login.

On the Web-based Management Device Homepage, under «options», «Anonymous Access» should be enabled when using ACU.

When clicking on a controller that is currently being configured in a different ACU session, a message will appear which allows you to override the other ACU session or cancel. If you choose to override the other ACU session, any unsaved changes in the other session will be discarded.

To uninstall ACU, use Add/Remove Programs located in the Control Panel on Windows Systems.

To run ACU in local application mode on Windows, Internet Explorer must be the default browser.

The following are known issues:

  • Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.
  • When using Linux as the host operating system, if a Smart Array controller has 16 or more volumes configured, deleting any volume in the ACU will not update the /proc/partitions to reflect the deletion of the device node associated with that volume. Rebooting the server will cause the update to happen. Note that there is also a limitation that only the first 16 volumes configured will be available to the operating system.

Release Notes

End User License Agreements:Hewlett-Packard End User License Agreement

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Important:

HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.  HP Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HP SSA, with the appropriate firmware.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices.  Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Notes:

For support for HP SSA or Smart Array controllers, please visit Contact HP.

Users will automatically be logged out after a predetermined period of inactivity when using HP SSA and will have to re-login.

On the Web-based Management Device Homepage, under «options», «Anonymous Access» should be enabled when using HP SSA.

When clicking on a controller that is currently being configured in a different HP SSA session, a message will appear which allows you to override the other HP SSA session or cancel. If you choose to override the other HP SSA session, any unsaved changes in the other session will be discarded.

To uninstall HP SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.

To run HP SSA in local application mode on Windows, Internet Explorer must be the default browser.

The following are known issues:

Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.

Release Notes

End User License Agreements:Hewlett-Packard End User License Agreement

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Important:

HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.  HP Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HP SSA, with the appropriate firmware.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices.  Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Notes:For support for HP SSA or Smart Array controllers, please visit Contact HP.

Если программа HP Smart Install не запускается автоматическ.

Если программа HP Smart Install не запускается автоматически, то на компьютереотключена функция автозапуска. Для запуска программы откройте окно «Мойкомпьютер» и дважды щелкните на значок диска HP Smart Install. Если вы не можетенайти диск HP Smart Install, используйте установочный диск устройства для установкипрограммного обеспечения.

Если программа запрашивает выбор типа подключения, выберите тип подключения,которое будет использоваться для печати после установки программного обеспечения.

Для завершения установки устройства выполните инструкции на экране.

Если вы хотите убедиться, что устройству был присвоен сетевой IP-адрес, то послеустановки устройства распечатайте страницу конфигурации. Для печати страницыконфигурации нажмите и удерживайте нажатой кнопку отмены на устройстве до техпор, пока не начнет мигать индикатор готовности , затем отпустите кнопку отмены.

Установка устройства с подключением к беспроводной сети припомощи установочного компакт-диска

Вставьте установочный компакт-диск с программным обеспечением в устройство чтениякомпакт-дисков компьютера.

Если программа установки не запустится автоматически, просмотрите содержимое компакт-диска и запустите файл SETUP.EXE.

Для завершения установки устройства выполните инструкции на экране.

Если вы хотите убедиться, что устройству был присвоен сетевой IP-адрес, то послеустановки устройства распечатайте страницу конфигурации. Для печати страницыконфигурации нажмите и удерживайте нажатой кнопку отмены на устройстве до техпор, пока не начнет мигать индикатор готовности , затем отпустите кнопку отмены.

Глава 4 Подключение устройства

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with
this MD5 Checksum value:

cp017239.exe 709495e97b81c861da5b63f6b2ebf058

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the «Install» button to proceed with the installation. The utility will automatically be installed.

Enhancements

Upgrade Requirement:Optional — Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for the following controllers: 

  • HP Dynamic Smart Array B120i
  • HP Dynamic Smart Array B320i
  • HP Smart Array P822

Added support for Simplified Chinese
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:

  • Replace Array

    Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different.  This allows moving data from SATA to SAS, or SAS to SATA.  However, the drive types comprising the array must still be of the same type.

  • Heal Array

    Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement.  The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives.  The operation will be available only if enough unassigned physical drives of the correct size are available.

  • Spilt Mirror Backup\Rollback

    • Create Split Mirror Backup

      • This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:

        • If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
        • If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
        • If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
        • The backup array always contains RAID 0 logical drives.
        • The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
      • This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
    • Manage Split Mirror Backup

      • This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:

        • Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
        • Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
        • Activate the backup array. This option makes the backup array fully accessible to the operating system.

Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with
this MD5 Checksum value:

5814a22364376d33a98682e9aaef29a6 cp015778.exe

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the «Install» button to proceed with the installation. The utility will automatically be installed.

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with
this SHA-256 Checksum value:

57cd27bf0d791695ea88aae6b0d0712de36fde3109534aed9ac6aabfb8681e5a cp027018.exe

Reboot Requirement:Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the «Install» button to proceed with the installation. The utility will automatically be installed.

Description

The Offline HP Smart Storage Administrator (HP SSA) provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows.

This deliverable will allow users to boot into an environment from which they can choose various configuration utilities (HP SSA, HPSSACLI, and HPSSASCRIPTING) prior to the Host OS loading.

The HP Smart Storage Administrator (HP SSA) helps you configure, manage, diagnose, and monitor HP ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HP Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Description

The HP Smart Storage Administrator (HP SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HP ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HP Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HP SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HP Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HP SSA, with the appropriate firmware.

HP SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Adblock
detector